Key facts
| Parameter | Value |
|---|---|
| Class | C250 |
| Test load | 250 kN |
| EN 124 group | 3 |
| Typical locations | Kerb-side gutters: ≤ 0.5 m into the carriageway, ≤ 0.2 m onto the footway |
| Typical materials | Ductile cast iron (GGG40/50); some composite |
| Shapes | Round, square, blind, kerb / side-inlet |
| Standard | EN 124-1 plus the material part (-2 cast iron, -5 composite, -6 plastic) |
| Availability | By quote: stock and lead time confirmed by sales |
Where class C250 is used
- Kerb inlets and side-inlet covers
- Gully gratings and covers in the road channel
- Road shoulders within the 0.5 m / 0.2 m limits; beyond them use D400
Materials and shapes
C250 is mostly ductile cast iron (GGG40 / GGG50). A few composite covers reach C250, but in the kerb zone cast iron is the safer default. Kerb (road-border) and side-inlet shapes are available.
How to write it in the BOQ
Kerb inlet cover and frame, ductile iron, EN 124 C250, road-border type, set in the channel at finished road level.
Selection mistakes to avoid
- Using C250 where wheels regularly cross the cover: that is D400.
- Setting a kerb cover higher than the channel so that water bypasses the inlet.
- Forgetting that the 0.5 m / 0.2 m limits are measured from the kerb edge.