Infrastructure project supply across Georgia · since 2019
HDPE corrugated pipe

Large-diameter corrugated pipe, 1600–3000 mm

For culverts, trunk storm collectors and large sewers, steel and concrete are heavy and slow to lay. HDPE corrugated pipe in 1600 to 3000 mm is light for its size, corrosion-free and laid in long runs. GON's range reaches Ø3000 mm in SN4 to SN12. Send the flow, slope and trench depth and we will suggest the size and class.

Ø1600–3000 mmSN4–SN12EN 13476-3Project supply

Large sizes at a glance

Size range, mmTypical useNotes
1600–1800Trunk storm collectors, large culvertsSN class by diameter confirmed in the quote
1800–2000Culverts under roads and embankmentsWall type and joint per datasheet
2000–2400Stormwater conveyance, large outfallsDelivery planned per project
2400–3000Largest culverts and collectorsProject-specific: send drawings

Where large corrugated pipe is used

  • Culverts under roads, railways and embankments
  • Trunk storm collectors for districts and highways
  • Large sewers and outfalls
  • Stormwater storage and conveyance where a long clear run is needed

Structural design and SN class

At these diameters the ring stiffness class is not chosen by diameter alone. It follows from the structural design: burial depth, soil, groundwater, traffic and bedding. The GON range covers SN4 to SN12; which class is made at which diameter is confirmed by the manufacturer's datasheet and stated in the quote.

Ask the designer for the structural calculation, or send us the longitudinal section and we will match the pipe to it.

Transport and installation

  • Large pipe is bulky: agree the delivery route, unloading and storage before ordering.
  • Bedding, side fill and compaction carry the load, so the trench design matters more as the diameter grows.
  • Lengths and joints differ by manufacturer and diameter: confirm them in the datasheet.

How to write it in the BOQ

“HDPE structured-wall corrugated pipe DN/ID 2000, ring stiffness SN [__] per structural design, EN 13476-3, with joint per manufacturer's datasheet; supply and laying on prepared bedding.”

FAQ

Large-diameter pipe questions

Can't find the answer? Call the sales desk.

+995 595 818 800
What is the largest size you supply?

The range reaches Ø3000 mm in SN4 to SN12. Availability by size and class is confirmed per project.

Which SN class do I need at 2000 mm?

That comes from the structural design of the trench, not from the diameter. Send the burial depth and loads and we will suggest a class.

Can it replace a concrete culvert?

Often, for road and drainage culverts, with a lighter and faster installation. Check the design loads and the authority's requirements first.

Project supply

Planning a large culvert or collector?

Send the flow, slope, trench depth and quantity. Sales replies with sizes, SN class and the manufacturer's documents.