Infrastructure project supply across Georgia · since 2019
HDPE corrugated pipe

SN8 corrugated drainage pipe, DN200–DN600

SN8 (ring stiffness of at least 8 kN/m²) is the usual class of double-wall HDPE corrugated pipe for storm and sewer lines under roads and developments. This page lists the five common sizes, 200 to 600 mm, and the BOQ wording.

SN8 ≥ 8 kN/m²DN/ID 200–6006 m lengthsEN 13476-3

SN8 sizes at a glance

Nominal size (DN/ID)Ring stiffnessLengthTypical use
200SN86 mProperty and gully connections, small branch lines
300SN86 mBranch collectors, road gully lines
400SN86 mStreet collectors, development networks
500SN86 mLarger collectors, culvert crossings
600SN86 mMain storm collectors, culverts

What SN8 means

Ring stiffness SN is the pipe's resistance to ring deflection under load, in kN/m², tested to EN ISO 9969. SN4, SN8 and SN12 are the usual classes and GON supplies SN4 to SN12.

SN8 is the common choice under roads and in ground with normal cover. SN4 suits shallow, lightly loaded lines; SN12 suits deep or heavily loaded trenches. The right class comes from the structural design of the trench (cover, soil, traffic), not from the diameter alone.

Standard and construction

Double-wall pipe to EN 13476-3 has a smooth inner bore and a corrugated outer wall. The smooth bore keeps flow capacity high and the pipe easy to clean; the corrugation gives the ring stiffness at low weight. Lengths are 6 m, joined with a socket and sealing ring.

Outside diameter, wall thickness, mass and joint details for each size are in the manufacturer's datasheet, which we send with the quote.

Sizes above DN600

The GON range runs up to Ø3000 mm in SN4 to SN12. For DN800 and larger, send the flow, the slope and the trench depth and we will suggest the class and the supply split.

How to write it in the BOQ

“Double-wall HDPE corrugated pipe DN/ID 400, ring stiffness SN8, EN 13476-3, 6 m lengths with socket and sealing ring; laid on compacted sand bedding with sand side fill to the design.”

Installation basics

  • Bed the pipe on compacted sand or fine gravel and fill the sides in layers; never on stones or loose fill.
  • Keep the trench only as wide as the design needs: width and side compaction carry the load.
  • Check the joint and the seal before backfilling, and keep the minimum cover specified in the design.

Cover depth, bedding and backfill come from the project's structural design, not from this page.

FAQ

SN8 pipe questions

Can't find the answer? Call the sales desk.

+995 595 818 800
SN4, SN8 or SN12?

SN4 for shallow, lightly loaded lines, SN8 for most road and development drainage, SN12 for deep trenches or heavy loads. The trench design decides.

Is SN8 enough under a road?

With normal cover and proper bedding SN8 is the common choice under roads. For very deep or heavily loaded trenches, check SN12 with the designer.

Do you have sizes above DN600?

Yes, the range runs to Ø3000 mm. Send the BOQ line and the quantity for a quote.

Project supply

Need SN8 pipe for a drainage project?

Send the pipe schedule or the BOQ: sizes, lengths and site. Sales replies with a quote, lead time and the datasheets.