SDR to pressure rating (PE100)
| SDR | Pressure rating |
|---|---|
| 26 | PN6 |
| 21 | PN8 |
| 17 | PN10 |
| 13.6 | PN12.5 |
| 11 | PN16 |
| 9 | PN20 |
| 7.4 | PN25 |
Wall thickness by diameter
| Outside diameter, mm | SDR 11 (PN16) | SDR 17 (PN10) | SDR 26 (PN6) |
|---|---|---|---|
| 63 | 5.8 | 3.8 | — |
| 90 | 8.2 | 5.4 | 3.5 |
| 110 | 10.0 | 6.6 | 4.2 |
| 160 | 14.6 | 9.5 | 6.2 |
| 200 | 18.2 | 11.9 | 7.7 |
| 315 | 28.6 | 18.7 | 12.1 |
| 400 | 36.4 | 23.7 | 15.4 |
| 630 | 57.2 | 37.4 | 24.1 |
“—” means the combination is not in the common range. The full table (32 to 630 mm) with theoretical mass per metre is in the download below.
How PN follows from SDR
PN = 20 × MRS ÷ (C × (SDR − 1)). For PE100, MRS is 10 MPa and the design coefficient C is 1.25, so PN = 160 ÷ (SDR − 1), rounded to the standard series: SDR 11 gives 16 bar.
PN is the pressure at 20 °C over 50 years for water. At higher water temperatures the permitted pressure drops, so state the operating temperature in the BOQ.
Choosing SDR for a water main
- SDR 17 (PN10) for most distribution networks at moderate pressure.
- SDR 11 (PN16) for higher pressure, surge-prone sections, and where a thicker wall helps handling and jointing.
- SDR 26 (PN6) for low-pressure and gravity-assisted lines where the wall can be thinner.
- Fix the choice with the hydraulic design, including surge, not with the table alone.
Standards and jointing
Water pipe follows EN 12201; PE gas pipe follows EN 1555 and has its own pressure rules, so ask us for gas. Pipes are joined by butt fusion or electrofusion fittings; GON supplies PE fittings, valves and boxes with the pipe.
How to write it in the BOQ
“PE100 pressure pipe DN110 × 10.0 mm, SDR 11, PN16, EN 12201, for butt-fusion or electrofusion jointing.”
Where this pipe has been used
GON supplied high-pressure PE100 pipes to the World Bank–funded water-supply rehabilitation in Dmanisi and its 19 villages, and to the internal network in Akhaldaba and Itavaza.